    Data Centre Fire Engineering

    Mission-critical facilities demand continuity-focused fire strategies. Gas suppression, early detection, and compartmentation designed around operational resilience requirements.

    Data centres are the backbone of the modern economy. A single fire event can cause billions in losses, not from the fire itself, but from downtime. Magnus Opifex SEVEN designs fire strategies that go beyond life safety to protect business continuity, equipment integrity, and operational uptime — because in data centres, the fire you prevent is worth infinitely more than the one you fight.

    Senior-led
    Project Delivery
    Written
    Scope Before Work
    UK-wide
    Project Coverage
    Standards-based
    Technical Approach
    Challenges We Solve

    Key Challenges

    Gas Suppression Systems

    Designing and validating clean-agent (Novec, FM-200, IG-541) suppression systems that protect equipment without residue.

    VESDA & Aspirating Detection

    Very Early Smoke Detection Apparatus providing warning at the incipient stage — before flames even develop.

    Compartmentation Strategy

    Balancing fire compartmentation with the need for cable routing, airflow management, and hot/cold aisle containment.

    Lithium-Ion Battery Risks

    UPS battery rooms present thermal runaway risks requiring specialist detection, suppression, and ventilation strategies.

    Water-Free Zones

    Designing fire protection that avoids water in server halls — because water damage can be worse than fire damage.

    Uptime Certification

    Fire strategies aligned with Tier III/IV uptime requirements and insurer expectations for concurrently maintainable systems.

    What We Deliver

    Our Services

    Data Centre Fire Strategy
    Gas Suppression Design Review
    VESDA System Design
    UPS Battery Room Fire Safety
    Compartmentation Design
    Cable Route Fire Protection
    Business Continuity Fire Planning
    Insurance Risk Reports
    Fire Risk Assessments
    Expert Witness
    Sector reality

    What makes data centres fire safety different

    The occupant load is tiny and the asset value is enormous, so the commercial question is continuity and equipment protection rather than escape capacity.

    Water-based protection in a live technical space can cause more loss than the fire, which forces the strategy towards early detection and carefully justified suppression choices.

    Energy-storage and UPS rooms introduce a thermal-runaway failure mode that behaves nothing like a conventional compartment fire.

    Who we usually work with

    • ·Data centre developers and operators
    • ·Critical-environment design teams
    • ·Facility and continuity managers
    • ·Insurance and risk stakeholders
    Regulatory position

    Which requirements typically apply, and how

    Regulatory Reform (Fire Safety) Order 2005, as amended by the Fire Safety Act 2021

    Applies to the premises as a workplace in England and Wales, whatever the continuity requirement.

    Building Regulations and Approved Document B

    Applies to building work; large technical halls are commonly justified through a performance-based route.

    Insurer and operator continuity requirements

    Contractual requirements set by the client's insurer or operator. They sit alongside the statutory minimum and are confirmed by the client, not assumed.

    Applicability is confirmed for the specific building. This is technical fire-safety consultancy and not legal advice; legal interpretation is a matter for your own advisers.

    Scope

    What you can instruct — and what is excluded

    Scoped deliverables

    • Fire strategy for technical halls, plant and support areas
    • Detection and suppression performance requirements and design review
    • Energy-storage and UPS room fire-safety review
    • Compartmentation strategy accommodating cable routes and airflow containment
    • Fire risk assessment for the operating facility

    Boundaries of the work

    • ·Suppression system design, commissioning and certification remain with the installing specialist; we set and review the performance requirement.
    • ·Uptime, resilience and operator certification schemes are the client's commercial arrangements; we do not certify or award any tier or rating.
    • ·This is technical fire-safety consultancy. Magnus Opifex Seven is not a building control authority, not the Building Safety Regulator, and not a certification body.
    • ·We do not take on Responsible Person, Accountable Person, Principal Designer or Principal Contractor duties, and no approval outcome, programme or cost is guaranteed.
    • ·British Standards and PAS documents are standards and guidance, not legislation; where they are referenced the statutory position is stated separately.
    • ·We do not issue or sign EWS1 forms. EWS1 is a valuation-related form for lenders and is not a life-safety certificate or a fire risk assessment.
    • ·Scope, fees and programme are confirmed in a written quotation once the building information is reviewed.
    Next step

    What we need to scope your enquiry

    Information needed

    • ·Hall areas, IT load and the containment arrangement
    • ·Energy-storage technology and room arrangement
    • ·Existing detection and suppression provision
    • ·Any insurer or operator requirement already issued

    Scope your data centre

    Send the hall arrangement, IT load and existing protection provision. You get a written scope stating what is assessed, what is reviewed and what remains with your installers.

    Discuss a data centre

    Ready to Discuss Your Data Centres Project?

    Tell us about the building and the fire-safety question you need answered. We confirm what is in scope, what evidence is missing, and the fee — in writing, before work begins.

    MO7

    Magnus Opifex SEVEN LTD

    Fire Safety & Fire Engineering Consultancy — London, UK

    Ready to Protect Your Next Project?

    From concept design to regulatory compliance, our fire engineering scope covers fire strategy, fire risk assessment, CFD smoke modelling and Building Safety Act 2022 support. Send project details for a scoped quotation.

    Founders & Leadership

    NS

    Nicoleta Vasile, Baroness of Brattleby

    Founder & CEO · Chief Legal Officer · Romanian-qualified Lawyer

    AS

    Alina Scarlat

    Technical Director & Fire Engineer (BEng)

    RV

    Răzvan Vasile

    Co-Founder & Chief Financial and Strategy Officer

    Head Office: 167-169 Great Portland Street, 5th Floor, London W1W 5PF
    © 2026 Magnus Opifex SEVEN LTD. All rights reserved.

    Send Inquiry

    Project enquiry · Written reply

    0/3000