Proposed scheme or developing design
A design fire strategy is developed with the proposed scheme and records the fire-safety design basis, coordinated provisions and assumptions for the project team to carry forward.
A written fire strategy your design team and reviewers can follow.
Scoped
written quotation against a defined scope
Coordinated
developed with the design team information provided
Documented
assumptions, limitations and provisions recorded
A fire strategy is a written document that explains how fire safety is intended to work in a specific building or project. It records the design basis and assumptions, the escape and evacuation principles, how fire spread is limited internally and externally, how detection, alarm, suppression and smoke-control systems interface, the basis for structural fire resistance, and the access and facilities intended for the fire and rescue service.
The document route and guidance used depend on jurisdiction. England, Wales, Scotland and Northern Ireland have different statutory and guidance routes: Approved Document B applies to England, with separate guidance in Wales, Scotland (Technical Handbooks) and Northern Ireland (Technical Booklet E). Building Safety Act 2022 and Building Safety Regulator Gateway duties apply to higher-risk buildings in England. The applicable design route and standards, including whether BS 9991 or BS 9999 is used, are agreed for each project based on jurisdiction, building type, project stage and scope.
A fire strategy is not a fire risk assessment. A fire risk assessment addresses duties for a building in use; a fire strategy sets out the fire-safety design basis for a project or an existing building's design intent.
A design fire strategy is developed with the proposed scheme and records the fire-safety design basis, coordinated provisions and assumptions for the project team to carry forward.
A retrospective fire strategy reconstructs the existing building's fire-safety basis from available records, surveys and observed conditions, with unresolved evidence recorded as gaps rather than approval.
Explore retrospective fire strategyWhen this service is useful
A fire strategy report that sets out the fire-safety basis of the design for a specific project: the assumptions, the design route agreed for the applicable jurisdiction, and the provisions the design team and dutyholders need to carry through. It supports design development and regulatory review; it does not grant or guarantee approval.
Primary outcome
A written fire strategy report, scoped to the project stage, jurisdiction and building use, with assumptions and limitations recorded.
New build project requiring a fire-safety design basis
Extension or alteration to an existing building
Refurbishment where fire-safety provisions change
Change of use altering occupancy, escape or risk profile
Planning or building-control comments to be addressed
Review or update of an existing fire strategy
Typical outputs for this service are listed below. The exact format — report, review notes, survey record or technical position — is confirmed in the agreed appointment, and each records the information supplied, the assumptions used and the limitations that apply.
The scope is set from the building facts, drawings, jurisdiction, project stage and the question the written output needs to answer.
Scope point 01
Jurisdiction, building use, project stage and the intended approval route are established before a fee is quoted, so the deliverable matches the project.
Scope point 02
The strategy is developed against the drawings and information provided, and interfaces with architecture, structure and building services are set out explicitly.
Scope point 03
Assumptions, limitations and the information relied upon are recorded in the report so the design team and dutyholders can see what the strategy depends on.
Every stage records what has been supplied, what remains open and what the report can and cannot conclude.
01
We confirm the project stage, jurisdiction, building use, height and intended approval route, and agree the scope in writing.
02
We review the drawings, existing reports and any reviewer comments supplied, and identify information gaps.
03
We set out escape, compartmentation, external spread, systems interfaces, structural fire resistance basis and fire service provisions for the agreed design route.
04
We issue the written fire strategy report with assumptions, limitations and the provisions the design team needs to carry through.
05
Responses to review comments, revisions and further design stages are handled as separately scoped work.
A simplified view of the sequence described above. The actual steps, inputs and outputs are confirmed in the written scope for your project.
Recorded basis
The project stage, jurisdiction, building use, drawings and intended approval route are defined before a quotation is issued.
Result
The report records the fire-safety design basis for the project; outcomes and approval decisions remain with the relevant dutyholders and authorities.
Explore the scope recorded for each project.
Fire Strategy for UK Building Projects
Use this as a checklist before you ask for a quotation. Tick what you hold; unknown items can be listed as unknown. Nothing here is saved.
Longer preparation aid: Fire strategy project-information checklist (free, no signup).
These are examples of building types, uses and project contexts for which this service scope is suitable. They are scope examples, not a client list or a record of completed instructions.
A written document setting out the fire-safety basis of a specific building or project: the assumptions relied on, escape and evacuation principles, internal and external fire spread provisions, systems interfaces, structural fire resistance basis, fire service access and the management information needed.
As early as the design allows, typically at concept or planning stage, and again when the design, use or occupancy changes. Early input means fire-safety provisions can shape layout and systems rather than be retrofitted into a fixed design.
It depends on jurisdiction, project type and building. There is no single UK requirement for a document with that title. In practice a fire strategy is commonly used to demonstrate how the fire-safety requirements of the building regulations for the relevant jurisdiction are addressed, and to support planning, building-control or regulator review. Whether one is needed, and in what form, is confirmed for each project.
A fire strategy sets out the fire-safety design basis of a project or building. A fire risk assessment addresses the duties of the Responsible Person for a building in use under the Regulatory Reform (Fire Safety) Order 2005 as amended by the Fire Safety Act 2021, which applies to premises in England and Wales; Scotland and Northern Ireland have their own separate operational fire-safety regimes. They are separate deliverables with different purposes.
Site address and jurisdiction, building use and occupancy, height and storeys, project stage, available drawings, any existing strategy or reports, the proposed changes, any known reviewer comments, and the programme you need to work to.
Yes. An existing strategy can be reviewed against the current design, use and applicable guidance, and updated or reissued where the scope for that work is agreed.
No. Modelling is only included where it is separately scoped and technically justified, for example where the design departs from the guidance route and quantitative evidence is needed.
No. The report supports design development and regulatory review. Approval decisions rest with the relevant authority, and the duties of clients, designers, contractors and other dutyholders are unchanged.
No. England, Wales, Scotland and Northern Ireland have different statutory and guidance routes. Approved Document B applies to England; Wales, Scotland and Northern Ireland use their own guidance. Building Safety Act 2022 and Building Safety Regulator Gateway duties apply to higher-risk buildings in England.
Request a written scope
Send the drawings, the building use, the jurisdiction, the project stage and the programme you need to work to. We will confirm the scope required for a written quotation.
Related services
Use these links when the building question also involves design strategy, operational risk, regulatory route mapping or evidence coordination.
Existing-building design basis
Evidence-based retrospective fire strategies for existing UK buildings where the design basis is missing, fragmented or outdated. Request a scoped review.
Explore Retrospective Fire StrategySmoke, heat and evacuation analysis
Computational fire, smoke and evacuation modelling for UK buildings. Send the drawings, the design question and the project stage for a scoped quotation.
Explore Fire & Smoke ModellingRegulatory route-finding
Fire-safety regulatory route mapping for UK projects: applicable duties, evidence gaps and dutyholder responsibilities. Send the project details for a scoped review.
Explore Legislative ConsultancyFire Safety & Fire Engineering Consultancy — London, UK
From concept design to regulatory compliance, our fire engineering scope covers fire strategy, fire risk assessment, CFD smoke modelling and Building Safety Act 2022 support. Send project details for a scoped quotation.
Nicoleta Vasile, Baroness of Brattleby
Founder & CEO · Chief Legal Officer · Romanian-qualified Lawyer
Alina Scarlat
Technical Director & Fire Engineer (BEng)
Răzvan Vasile
Co-Founder & Chief Financial and Strategy Officer
Head Office: 167-169 Great Portland Street, 5th Floor, London W1W 5PF
© 2026 Magnus Opifex SEVEN LTD. All rights reserved.