    Fire and Smoke Modelling for UK Buildings

    Quantified evidence for the design question prescriptive guidance cannot answer.

    Scoped

    written quotation against a defined modelling question

    Documented

    inputs, assumptions and limitations recorded

    Sensitivity

    agreed scenario and sensitivity cases, not a single run

    What fire and smoke modelling is, and when it helps

    Computational modelling is used when a fire-safety design question cannot be answered clearly by following prescriptive guidance alone. Typical questions concern how smoke moves through a large or connected volume, how long conditions on an escape route remain tenable, whether a smoke-control arrangement performs as intended, and how long occupants realistically take to leave.

    A performance-based analysis is carried out within an agreed framework: the question and acceptance criteria are defined first, the design fires and scenarios are justified, the geometry and boundary conditions are built from the information supplied, and sensitivity cases test whether the conclusion survives reasonable changes in assumption. In the UK, performance-based design is commonly framed using BS 7974 and its published documents, with BS 9999 or BS 9991 used where a project follows those routes. These are British Standards and guidance, not legislation.

    Modelling supports an argument; it does not replace one. The value of a model depends on whether its inputs are justified and its limitations are stated. Where the information needed to justify an input has not been supplied, that gap is recorded as a limitation rather than assumed.

    When this service is useful

    Modelling is most useful while the design can still change and before a reviewer's comment becomes a redesign.

    Computational modelling of smoke movement, tenability and occupant evacuation for a specific building and a specific design question, delivered as a written technical report with the inputs, assumptions, sensitivity cases and limitations recorded. It supports design development and regulatory review; it does not grant or guarantee approval.

    Primary outcome

    A written modelling report that states the question, the scenarios examined, the results obtained and the limits of what the results support.

    Atria, basements, large-volume or connected spaces

    Extended travel distances or a non-standard escape strategy

    A decision between natural and mechanical smoke ventilation

    A reviewer or approval body has asked for quantitative evidence

    A smoke-control or sprinkler interface is being value-engineered

    An occupant evacuation assumption needs testing rather than asserting

    What you receive

    Clear outputs you can act on.

    Typical outputs for this service are listed below. The exact format — report, review notes, survey record or technical position — is confirmed in the agreed appointment, and each records the information supplied, the assumptions used and the limitations that apply.

    Defined modelling question and acceptance criteria

    Scenario matrix with design-fire and ventilation rationale

    Computational geometry and boundary-condition record

    Smoke, temperature, visibility and tenability outputs

    Available and required safe escape time comparison where in scope

    Evacuation modelling interface where separately scoped

    Written technical report with assumptions and limitations stated

    How we scope and coordinate the work

    The service is defined before the fee is quoted.

    The scope is set from the building facts, drawings, jurisdiction, project stage and the question the written output needs to answer.

    Scope point 01

    The question is fixed first

    The report states the design question and the acceptance criteria before any scenario is run, so the output answers a decision rather than filling a folder.

    Scope point 02

    Assumption ledger

    Inputs, boundary conditions, design fires and limitations are written down explicitly so the analysis can be reviewed and defended.

    Scope point 03

    Sensitivity before conclusion

    Agreed sensitivity cases test whether the conclusion holds under reasonable changes of assumption instead of resting on a single favourable run.

    From enquiry to written report

    A clear sequence from information request to issued output.

    Every stage records what has been supplied, what remains open and what the report can and cannot conclude.

    01

    Question framing

    We define, in writing, what the modelling must demonstrate and which design or review decision it supports.

    02

    Scenario matrix

    We agree credible fire locations, growth assumptions, ventilation states and occupant assumptions with their rationale.

    03

    Model build

    We build geometry, boundary conditions and outputs from the supplied information and record every assumption made.

    04

    Simulation and sensitivity

    We run the agreed core and sensitivity cases and check outputs for consistency and anomalies.

    05

    Reported conclusion

    We translate the outputs into a written conclusion, stating what the results support and where they stop.

    How the evidence becomes a written output

    A simplified view of the sequence described above. The actual steps, inputs and outputs are confirmed in the written scope for your project.

    Three-step diagram: design question and drawings, agreed scenarios and model with logged assumptions, technical report with stated limits
    Illustrative process for fire and smoke modelling, not a simulation output or project drawing. Magnus explanatory illustration.

    Recorded basis

    A scoped, documented modelling process

    The design question, acceptance criteria, scenarios and information supplied are recorded in writing before a fee is quoted.

    Question and acceptance criteria agreed first
    Design-fire and ventilation assumptions justified in the report
    Sensitivity cases agreed rather than added afterwards

    Result

    The output records the scenarios examined, the results obtained from the information supplied, and the limitations that bound them. Approval and regulatory determination remain with the relevant authorities.

    Related project records

    Explore the scope recorded for each project.

    Prepare your project brief

    What we need from you to scope the work.

    Fire and Smoke Modelling for UK Buildings

    Use this as a checklist before you ask for a quotation. Tick what you hold; unknown items can be listed as unknown. Nothing here is saved.

    Request a scoped quotation
    Scope boundaries

    What this service does not include.

    • Modelling supports a design argument; it is not a building-control or Building Safety Regulator approval and does not guarantee approval.
    • The modelling approach, software and mesh strategy are confirmed per project in the written scope; no specific tool is promised in advance.
    • Results are only valid for the geometry, scenarios and assumptions recorded in the report.
    • Where the information needed to justify an input is not supplied, it is recorded as a limitation, not assumed.
    • A modelling report is not a fire risk assessment, a fire strategy, a fire-door inspection or an installation certificate unless separately scoped.
    • Structural fire analysis, evacuation modelling and external fire spread work are included only where separately scoped.
    • Fees and programme are confirmed in a written quotation after the modelling question and scope are agreed.
    Suitable scope examples

    Buildings and uses this service scope suits.

    These are examples of building types, uses and project contexts for which this service scope is suitable. They are scope examples, not a client list or a record of completed instructions.

    • Atria and multi-storey connected volumes
    • Basements and below-ground occupied space
    • Large retail, leisure and assembly spaces
    • Transport and interchange environments
    • Industrial and warehouse volumes
    • Mixed-use developments with shared escape routes
    • Refurbishments where prescriptive guidance cannot be met directly
    Client needs

    How this service supports project and building teams.

    Architects
    Quantified evidence for a defined design question where prescriptive guidance does not resolve the issue.
    Developers
    A documented analysis that supports an informed design decision without promising approval or savings.
    Building engineers and surveyors
    Transparent scenarios, assumptions and sensitivity results for technical coordination and review.

    Questions about this service

    Is modelling always required?

    No. It is most useful when prescriptive guidance cannot answer the design question clearly, or when a reviewer has asked for quantitative evidence. Where prescriptive guidance answers the question, modelling adds cost without adding certainty.

    Which software do you use?

    The modelling approach and software are confirmed for each project in the written scope, based on the question being answered, and are stated in the report alongside the version used.

    What makes a modelling report credible?

    A clearly stated question, justified inputs, agreed sensitivity cases, transparent limitations, and conclusions tied directly to the decision the report supports.

    Can modelling reduce cost?

    It can, where evidence shows a simpler or better-targeted arrangement still meets the agreed criteria. It can also show the opposite. No saving is promised in advance.

    Does a model guarantee approval?

    No. Building control, the Building Safety Regulator or the relevant approval body decides the outcome. The report provides evidence for that decision; it does not make it.

    Request a written scope

    Send the drawings and the design question. We will scope the modelling.

    Provide the drawings, the building use, the jurisdiction, the project stage and the specific question or reviewer comment the modelling must address. We will respond with the scope required for a written quotation.

    MO7

    Magnus Opifex SEVEN LTD

    Fire Safety & Fire Engineering Consultancy — London, UK

    Ready to Protect Your Next Project?

    From concept design to regulatory compliance, our fire engineering scope covers fire strategy, fire risk assessment, CFD smoke modelling and Building Safety Act 2022 support. Send project details for a scoped quotation.

    Founders & Leadership

    NS

    Nicoleta Vasile, Baroness of Brattleby

    Founder & CEO · Chief Legal Officer · Romanian-qualified Lawyer

    AS

    Alina Scarlat

    Technical Director & Fire Engineer (BEng)

    RV

    Răzvan Vasile

    Co-Founder & Chief Financial and Strategy Officer

    Head Office: 167-169 Great Portland Street, 5th Floor, London W1W 5PF
    © 2026 Magnus Opifex SEVEN LTD. All rights reserved.

    Send Inquiry

    Project enquiry · Written reply

    0/3000