Sellafield estate, Cumbria · wider passive fire-protection experience on defined building packages

    Fire compartmentation surveys

    Estate and remediation teams: locate compartment-line and fire-stopping defects before defining repairs, with a referenced findings schedule, photographs and agreed access or opening-up limits.

    Sellafield, Cumbria · Compartmentation and fire-stopping evidence review within defined building packages.

    Access, sampling and any opening-up are agreed first; concealed construction is not assumed compliant.

    Sellafield estate, Cumbria · wider passive fire-protection experience on defined building packages

    Request a compartmentation survey quote

    We will clarify your scope before preparing a written fee proposal.

    Outline the building or portfolio, project stage and decision you need to make. Do not include confidential information or attach documents here.

    Add project details or phone (optional)
    Your role (optional)

    No obligation. Your details help us scope the work properly. We’ll respond by email.

    Prepare a detailed project brief

    Selected clients and project experience

    • Sellafield Nuclear Facility
    • Battersea Power Station
    • Co-op Live
    • Wimbledon Quarter
    • The Triangle
    • Google Data Centres (3)
    • Google Bay View (HQ)
    • Novotel
    • Westminster City Hall
    • Chelsea and Westminster Hospital
    • Wembley Stadium
    • Tottenham Hotspur Stadium
    • Etihad Stadium (Manchester City)
    • Stamford Bridge (Chelsea FC)
    • Craven Cottage (Fulham FC)
    • Sports Stadium 2, Qatar
    • Allianz Stadium, Twickenham
    • Emirates Stadium (Arsenal)
    • King Power Stadium (Leicester City)
    • Coca-Cola
    • Network Rail
    • TATA Group
    • Bain & Company
    • UBS
    • McLaren Group
    • Romulus Construction
    • Hermes
    • Collins Construction
    • Southwark Council
    • UAL — University of the Arts London
    • St Paul's Girls' School
    • Northampton Partnership Homes
    • BBC
    • Qatari Diar
    View projects

    What changes the cost and extent of a compartmentation survey?

    Start with the floors, compartment lines and service penetrations that need checking. Plans help locate each inspection; concealed construction may need further investigation before a finding can be made.

    The quotation depends on floors and lines covered, plans, access, sampling and separately agreed opening-up and reinstatement. Specify who authorises and carries out intrusive work, occupied-area constraints and the required defect-record format.

    A defect schedule can identify the floor, room or grid line, the penetration, the photograph and any access limit. These illustrative fields show how the site team can find the same defect again and plan the next inspection or repair.

    Compartmentation is one of the most important passive fire protection measures in a building. Fire-resisting walls and floors divide the building into compartments designed to contain a fire in the compartment where it starts for a specified period. When the boundaries are continuous and their openings properly protected, they restrict fire spread and help limit the movement of smoke. A compartment may contain several rooms. A stated fire-resistance period describes performance under specified test conditions; it does not guarantee the duration of a real fire.

    20+ years
    Senior team experience
    3 continents
    Team project experience
    £10B+
    Portfolio development value
    900+
    Completed projects

    Experience reflects the senior team’s careers. Full development values of projects represented in the portfolio; Magnus delivered defined fire-engineering scopes. The 900+ figure covers completed projects across the Magnus portfolio, not clients or individual-service totals.

    Alina Scarlat leads the engineering interpretation of fire-resisting construction and evidence. The written appointment identifies the survey scope and any separately commissioned whole-building strategy review.

    About Magnus Opifex Seven

    What effective compartmentation protects

    This reduces the risk to life by helping to keep escape routes usable for the time people need to reach safety. By limiting the area affected by a fire, effective compartmentation can also reduce damage to the building and its contents, the cost of repairs and disruption to its use.

    Its life-safety role depends on the evacuation strategy. Simultaneous evacuation, progressive horizontal evacuation and stay-put arrangements, where appropriate, place different demands on the boundaries. Property protection and reduced business interruption are potential benefits; the survey does not guarantee an insurance outcome.

    Magnus Opifex Seven (MO7) provides compartmentation surveys for existing and new buildings. We offer these surveys alongside a whole-building fire strategy analysis. Our engineers identify the purpose of each boundary, examine the available evidence and explain what an observed defect means for the people and spaces that boundary protects.

    How the fire strategy informs our findings

    A fire-resisting boundary may protect the only escape stair, separate flats or allow patients to move horizontally into an adjoining compartment. Its purpose changes the consequence of a defect. When appointed to review the wider strategy, we consider how the compartment layout works with the evacuation arrangements, the needs of occupants, and relevant detection, smoke control and suppression measures.

    Existing and occupied buildings

    Alterations can leave openings where cables, pipes or ducts pass through fire-resisting construction. A wall that appears continuous from a corridor may stop short above a suspended ceiling. We use the available strategy, drawings, installation records and site evidence to identify the boundaries that need investigation. Where the design intent is uncertain, we record the assumption and explain how it can be checked.

    New construction and refurbishment

    We review the intended compartment layout and agree inspections at stages when the work can still be seen. Before a riser is enclosed or a ceiling closed, it may be possible to examine a wall head, a floor penetration or the fire-stopping around a duct. Recording a discrepancy at this stage gives the project team an opportunity to correct it and retain evidence before access is lost.

    Relevant passive fire-protection experience

    The wider appointment below provides context for our engineering experience. It is not presented as a completed compartmentation-survey commission.

    Sellafield estate

    Defined building packages on the Sellafield estate: review of site conditions, drawings and test evidence for structural fire protection, compartmentation, fire-stopping and fire doors, coordinated with the fire strategy.

    Read project overview

    What we inspect and report

    We agree the walls, floors and interfaces to be inspected. Depending on the project, these may include wall heads, floor edges, riser enclosures, fire doorset interfaces, service penetrations and dampers where ducts cross a fire-resisting boundary. We examine relevant cavity barriers where the agreed access allows.

    Compartment walls and floors create the enclosure; fire-stopping protects penetrations and joints; cavity barriers restrict spread within concealed cavities. Inspecting an interface with a door or damper is not a complete doorset inspection or a functional damper test.

    Your survey report

    You receive a report with a location-referenced schedule. For each significant finding we identify the intended function and performance where known, what we observed, the records or photographs supporting the finding, its significance for the fire strategy and the action we recommend. Actions may include obtaining installation evidence, targeted opening-up, remedial work or further fire-engineering review.

    For example, an open cable penetration beside the only escape stair warrants prompt attention if it breaches the stair enclosure. We identify the affected location, explain the potential for smoke to enter the stair and advise the client on the need for interim precautions while the permanent repair is developed.

    Illustrative finding record — not a project result

    This fictional, anonymised-style specimen shows one entry in a location-referenced photographic schedule. References are illustrative only: no actual survey, photograph, fire-resistance rating or safety conclusion is asserted. The agreed survey scope determines the locations and records covered.

    Location and drawing reference

    Example F-01 · Level 02, corridor beside riser R-02 · plan EX-02, revision A, grid C/4. Confirm the intended compartment line against the current fire-strategy drawing.

    Observation and photographic reference

    Example photo reference P-01: a visible gap beside a cable bundle at the accessible face of the wall. Record the view and location in the photographic schedule; appearance alone does not establish the concealed build-up or fire performance.

    Access limit

    Accessible corridor face only. The reverse face and the construction above the suspended ceiling were not inspected in this example. No conclusion is drawn about those areas.

    Next action

    Obtain the relevant drawing and installation evidence; agree targeted access or opening-up if needed to establish the detail. Review the evidence before defining a remedial detail. Opening-up and reinstatement responsibilities are separately agreed.

    Concealed construction and sampling

    A visual survey covers what can be seen at the agreed locations. Where a concealed detail is material to our conclusion, we identify the evidence needed and can specify targeted opening-up. Before intrusive inspection, we agree who will provide access, protect occupants during the work and reinstate the construction.

    The report identifies the locations inspected and any exclusions. If repeated defects suggest a wider issue, we explain why further inspection is warranted and where it should be directed. Conclusions about concealed or uninspected areas require additional evidence. A survey does not certify the building or installation.

    Can we commission related services?

    We can focus the survey on fire-stopping, agree a separate doorset inspection, or review proposed remedial details. Specialist testing and installation are separate appointments. A full fire strategy review or the preparation of a new strategy can be included in our written scope.

    A coordinated process

    1. 01

      Define the boundaries and priorities

      Review the available strategy, drawings and concerns. Identify the intended function and performance of the boundaries, including any assumptions.

    2. 02

      Inspect at an agreed stage

      Agree accessible locations, targeted opening-up and safe access. On construction projects, inspect relevant details before they are concealed.

    3. 03

      Interpret and report

      Issue a location-referenced schedule with observations, evidence, significance and recommended actions. Escalate material risks and explain where more evidence is needed.

    Before you enquire

    Send the building address and use, project stage, available plans and fire strategy, areas of concern, and any restrictions on access or opening-up. For occupied buildings, tell us how evacuation is managed. For construction projects, tell us when the relevant work will be concealed. If records are incomplete, send what you hold.

    Connected lifecycle services

    Projects may need several coordinated instructions; these are not automatically included in every appointment.

    Related services

    Sectors we work across

    Questions before commissioning

    Can you inspect a new building before work is concealed?

    We review the intended compartment layout and agree inspections at stages when the work can still be seen. Before a riser is enclosed or a ceiling closed, it may be possible to examine a wall head, a floor penetration or the fire-stopping around a duct. Recording a discrepancy at this stage gives the project team an opportunity to correct it and retain evidence before access is lost.

    Can you inspect concealed construction?

    A visual survey covers what can be seen at the agreed locations. Where a concealed detail is material to our conclusion, we identify the evidence needed and can specify targeted opening-up. Before intrusive inspection, we agree who will provide access, protect occupants during the work and reinstate the construction.

    What does a sample establish?

    The report identifies the locations inspected and any exclusions. If repeated defects suggest a wider issue, we explain why further inspection is warranted and where it should be directed. Conclusions about concealed or uninspected areas require additional evidence. A survey does not certify the building or installation.

    Does the survey include a complete fire door or damper inspection?

    The scope identifies the interfaces inspected. Complete doorset inspections, functional damper testing, specialist testing and installation are separate services unless expressly included.

    Can you also review the whole-building fire strategy?

    Yes. We can include a wider strategy analysis in a written appointment. A targeted compartmentation survey on its own does not establish the adequacy of the whole building.

    Plan the inspection while the evidence is accessible.

    Tell us which boundaries concern you, how the building is used and when the work will be concealed. We will define the survey and any additional engineering review.

    Request a compartmentation survey quote